ROUGH OPENING REQUIREMENTS
1. EXTERIOR FRAMES
2. POCKET FRAMES
*Frame opening 2" over double call out size in width and 4" over call out size in height
|
(1) Example: Single 2/6 x 6/8 opening - R.O. should be 62" w. x 84" h. |
|
(2) Example: Double 2/6 x 6/8 opening - R.O. should be 122" w. x 84" h |
|
3. METAL FRAMES
4. INTERIOR PREFITS
5. WARDROBE SLIDING BYPASS OPENINGS (with 1/2" drywall wrapped)
A) 6/8 Units with 2 doors
Frame opening at call out size in width and 2” over call out in height |
|
(1) Example: 2-door 8/0 x 6/8 opening – R.O. should be 96” w. x 82” h. |
|
|
B) 6/8 Units with 3 doors
Frame opening 1” under call out size in width and 2” over call out in height |
|
(1) Example: 3-door 12/0 x 6/8 opening – R.O. should be 143” w. x 82” h. |
|
|
C) 8/0 Units with 2 doors
Frame opening at call out size in width and 3/4” over call out in height |
|
(1) Example: 2-door 8/0 x 8/0 opening – R.O. should be 96” w. x 96-3/4” h. |
|
|
D) 8/0 Units with 3 doors
Frame opening 1” under call out size in width and 3/4” over call out in height |
|
(1) Example: 3-door 12/0 x 8/0 opening – R.O. should be 143” w. x 96-3/4” h. |
|
|
**NOTE**
For 8' ceiling height - 8' high openings should be framed at ceiling height and have continuous backing. |
|
|
6. BIFOLD OPENING (with 1/2" drywall wrapped)
**NOTE**
8' high openings should be framed at ceiling height and have continuous backing.
7. MEDICINE CABINETS
For openings with 26” mirrors frame 14” x 24” x 3-1/2”
For openings with 36” mirrors frame 14” x 34” x 3-1/2”
**NOTE: YOU MUST BE ABLE TO VERIFY THAT SHEAR PANEL IS COMPLETE FOR ALL UNITS SCHEDULED PRIOR TO RECEIVING EXTERIOR JAMB DELIVERY AND INSTALLATION.
|